Superconductivity and Magnetism

parent site logoSite logo

Group Research Facilities

[c]

The Superconductivity and Magnetism Group has a suite of state-of-the-art equipment that is operated and maintained by the Group. This apparatus is used for:

These facilities are available for use by members of the Department, the University, and, through collaborations, by external users.

If you would like to know more please contact a member of the Superconductivity and Magnetism Group (please see listings below).

During the course of our research work we also make regular use of a number of Central facilities here in the UK and abroad.


Equipment List and Specifications

  
Sample Preparation Facilities
Equipment
Specifications
External users 
Status

NEC SC-N35HD infra red image furnace

2 mirror furnace. Max. operating temperature 2000ºC.

Contact Geetha Balakrishnan for further details

Operational

Crystal Systems Incorporated F-ZT-10000-H-IV-VPS infra red image furnace

4 mirror furnace. Max. operating temperature 2000ºC. Chamber can be pumped to 10-6mbar using a turbo pump and then filled with O2, Ar, CO or various specific gas mixtures up to pressures of 10 atm.

Contact GB for further details

Operational

Crystal Systems Incorporated FZ-T-12000-X-VI-VP Xenon lamp image furnace

4 mirror furnace. Max. operating temperature 2800ºC. Chamber can be pumped to 10-6mbar using a turbo pump and then filled with O2, Ar, CO or various specific gas mixtures up to pressures of 10 atm.

Contact GB for further details

Operational
Canon Machinery SC1-MD11020 infra red image furnace 2 mirror furnace. Max. operating temperature 2000ºC. Contact GB for further details Operational
Argon shielded tri arc furnace Thoriated tungsten electrodes. Samples up to 8 cm in length and 1 cm in diameter prepared under 1 atm. flowing Ar gas.

Contact GB for further details

Operational
3 annealing furnaces Max. temperature 1600ºC. Treatment under flowing gases. Booking sheets open
2 box furnaces Max. temperature 1600ºC.   Booking sheets open
Three zone furnace Each zone is controlled separately with a max. operating temperature of 1200ºC. Booking sheet open
Philips PW1730 X-ray generator with Photonic-Science real time Laue system Photonic-Science high resolution Laue X-ray imaging system with Newport goniometer; Philips x-ray generator with Mo tube.

Contact Oleg Petrenko for further details

Booking sheets open

 

Laboratory Measurement and  Characterization Apparatus 
Equipment
Specifications
External users 
Status 

Quantum Design MPMS5S SQUID magnetometer

{M vs. T or M vs. H}

±5 T magnet. T range 1.8-400 K. Sensitivity 5×10-7 emu. Maximum sample size ~5×5×5mm3 and 3 emu. Contact MRL

Booking sheets open

AC susceptibility option under test

Quantum Design MPMS XL7 SQUID magnetometer

{M vs. T or M vs. H}

±7 T magnet. T range 1.8-400 K with oven option to 800 K. Sensitivity 5×10-7 emu. Maximum calibrated sample size ~9mm and 5 emu.

System includes transverse moment detection system and sample rotators.

Contact MRL

Booking sheets open

IQ2000-AGHS-2RSO Helium-3 system

{M vs. T or M vs. H}

T range 480 mK -1.8 K, background 2×10-4 emu at 5 T.

Used in conjunction with 7T QD MPMS SQUID magnetometer.

Contact MRL

Booking sheets open

easyLab Mcell10 pressure cell: used in conjunction with our SQUID magnetometers

Single wall cell. Hydrostatic pressures of 10 kbar. Sample space (1.9 mm diameter and 10 mm long). With automatic background subtraction min. sample signal ~1×10-5 emu.

See MRL Ready for use 

Quantum Design Physical Properties Measurement System (PPMS) (#1)

{C vs. T or H}

±9 T magnet. Heat capacity measurements using a relaxation method over the Trange 1.8-400 K. Base temperature 300 mK with He-3 insert and 50 mK with dilution refrigerator option. Contact MRL

Booking sheets open

Quantum Design Physical Properties Measurement System (PPMS) (#2)

{Rac and Rdc) vs. T,  H, or P}

{S and K   vs. T or H}

±9 T magnet, Trange 1.8 K to 400 K. Transport measurement:

AC transport option allows AC and DC resistivity, 4 and 5 wire balanced Hall effect and I-V curve measurements

Thermal transport option allows measurements of thermal conductance K  and Seebeck coefficient S.

Contact MRL

Booking sheets open

easyLab Pcell30 pressure cell: used in conjunction with our PPMS system. Cylindrical double-walled BeCu / super-alloy & WC Maximum pressure 3.0 GPa, pressure volume 2.9 mm dia. x 10 mm length, 6 Cu twisted pairs for AC transport  measurements. Contact MRL Est. operational mid Dec. 2009

Oxford Instruments vibrating sample magnetometer (VSM)

{M vs. T or M vs. H}

±12 T magnet. T range 1.4-300 K (50-1000 K with furnace insert). Sensitivity 5×10-6emu (1×10-4emu with furnace insert). Maximum sample size ~5×5×5mm3 and 300 emu. Contact MRL Booking sheets open

Oxford Instruments cryomagnet

(ESR measurements)

±9 T magnet. T range 1.4-300 K. Variable frequency ESR measurements. Contact OAP Warm - ready for use
3 ASR products orange cryostats T range 1.4-300 K. Inserts: heat capacity (adiabatic method), ac magnetic susceptibility (N.B. 20-10000 Hz, zero d.c. magnetic field) Contact MRL heat capacity insert awaiting repaired

Oxford Instruments Heliox He-3 insert

 {χa.c. vs. T or frequency}

 

Base temperature 320 mK with ac magnetic susceptibility stage. in use: final year project Testing

 

 